TemTop P200 Air Quality Detector

TemTop P200 Air Quality Detector

Product Overview: 
Laser particle detector can accurately detect indoor air quality. Adopting laser particle sensor, it can directly transform the concentration of pollutants in the air into visual data and provide air quality for you to effectively safeguard the health of your family.

Application Scope: 
At home, office, cab, etc.
 
Product Specifications: 
Name: Laser particle detector
Model: P200
Display mode: LCD screen
Battery voltage: AA battery * 3
Overall dimension: 168*65*32mm
Operating environment: Temperature range: 0-40℃; Humidity range: 15-90% RH; Atmospheric pressure condition: 1atm
PM2.5/10 measurement technical index: Range: 0-999ug/ m³; Resolution: 1ug/ m³
Health standard index:

        Status
Monitor
Good Normal Hazardous
PM2.5 <75 75~200 >200
PM10 <100 100~200 >200

Operation Method: 
1. Turn on/off the detector: 
Press and hold the power button for 1 second to turn on/off the detector. No operation for 5min, it will turn off, too.
2. Detect the concentration of PM2.5, PM10 
Turn on the detector and put it in the environment which needs testing, then the system will automatically detect the concentration of PM2.5, PM10.
3. Power indication:
The detector has the function of testing the battery power. When it is , the battery is full; When it shows
, the battery is low and the detector alarms.
4. Switch of display content
PM2.5 Button:  Press it and the system will enter PM2.5 index display interface.
PM10 Button:  Press it and the system will enter PM10 index display interface.
 Button: Press it and then the backlight is turned off; Press it again, the backlight will be turned on.
Play/Stop Button: Under the real-time detection mode, press the button and the current value will be maintained; Press the button again, the detector restore real-time detection mode in which the real-time value of environmental conditions will be showed.
 Button: Press the key in the low battery alarm state, the sound is turned off; Press it again, the sound is turned on.
5. Battery replacement
Replace the battery when the detector emits a low battery alarm. Method: use the thumb to press the arrow indicator area on battery cover, and slide the battery cover in the direction of the arrow. Then replace the battery.

Operation Notice:
1. The sensor used to detect PM2.5, PM10 adopts laser detection theory, so objects like battings and hair should be prevented from entering the detector to avoid influencing the accuracy of test data.
2. Don not put the detector in the environment where the concentration of particles is more than 500ug/m³ for long time. Long-time exposure to high-concentration air pollutants will damage the sensor and make it work improperly.
3. Avoid using the detector in humid environment to make sure the accuracy of test data.
4. Avoid bump, strike and drop.
5. Do not cover the detection port and air outlet port while using the detector.
6. Be cautious of cross interference.

Packing List:
Main machine……………………………………………………………1 Set
AA battery…………………………………………………………………3 Pieces
User manual………………………………………………………………1 Piece